Halogen-Free Security Cables & Wires
|
Halogen-Free Installation Cables: Overview
|
In all locations,
due to damages of large amount of materials
and more of importance to protect human
life and technical equipment against damages
caused by fire and also for technical enquiries
of insurance, the installation of halogen-free
security cables are required.
You will find on the next following pages
the instructions for installation as well
as the test methods and laying indications
of the halogen-free security cables.
|
The
most important advantages:
- No fire propagation at local flame influence
- Functionality for important systems
- No corrosion and damage by released corrosive
gases and vapors
- Protection of human life and valuable materials,
especially for high quality machines, EDP-systems
etc.
- Prevention of heavy and unexpected subsequent
damage
- Low smoke density helps rescue and fire extinguishing
works
|
|
|
Picture |
Type |
Description |
Approvals |
![H05Z-K / H07Z-K (Rubber insulated single conductor, Halogen-free)](../images/continue_arrow_black_red.gif) |
![H05Z-K / H07Z-K rubber insulated single conductor, halogen-free, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/control/small/H05Z-K_H07Z-K.jpg) |
H05Z-K / H07Z-K |
Rubber Insulated Single Conductor, Halogen-Free |
![Euro](../images/approvalpics/small_approvalpics/euro.gif) |
![J-2Y(St)H (St ||| Bd 16 Mbits/s (Kat.3) ISDN.EDV (Z=100 Ohm), Installation Cable, Halogen-Free)](../images/continue_arrow_black_red.gif) |
![J-2Y(St)H St ||| Bd 16 Mbits/s (Kat.3) ISDN/EDV (Z = 100 Ohm), halogen-free, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/J-2Y(St)H.jpg) |
J-2Y(St)H |
St ||| Bd 16 Mbits/s (Kat.3) ISDN/EDV (Z=100 Ohm), Installation Cable, Halogen-Free |
- |
![JE-H(St)H (Bd Fe 180/E 30 to E 90 (orange), Industry-Electronic Cable)](../images/continue_arrow_black_red.gif) |
![JE-H(St)H Bd FE 180/E 30 to E 90 (orange), halogen-free, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/JE-H(St)H.jpg) |
JE-H(St)H |
Bd Fe 180/E 30 to E 90 (Orange), Halogen-Free, Industry-Electronic Cable |
- |
![JE-H(St)H (Bd Fire Warning Cable, FE 180/E 30 to E 90, Outer Jacket Red, Halogen-Free)](../images/continue_arrow_black_red.gif) |
![JE-H(St)H Bd Fire warning cable, FE 180/E 30 to E 90 (red), halogen-free, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/JE-H(St)H_fire.jpg) |
JE-H(St)H (Fire) |
Bd Fire Warning Cable, FE 180/E 30 to E 90, Outer Jacket
Red, Halogen-Free |
- |
![JE-H(St)HRH (Bd Fire Warning Cable, FE 180/E 30 to E 90, Galvanized Steel Wire Braiding, Outer Jacket Red)](../images/continue_arrow_black_red.gif) |
![JE-H(St)HRH Bd Fire warning cable, FE 180/E 30 to E 90, halogen-free, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/JE-H(St)HRH.jpg) |
JE-H(St)HRH |
Bd Fire Warning Cable, FE 180/E 30 to E 90, Halogen-Free, Outer Jacket Red |
![VDE Approval](../images/approvalpics/small_approvalpics/vde.gif) |
![JE-LiHCH (Bd Industry Electronic Cable, Halogen Free, According to VDE 0816)](../images/continue_arrow_black_red.gif) |
![JE-LiHCH Bd Industry electronic cable, halogen-free, according to VDE 0816, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/JE-LiHCH.jpg) |
JE-LiHCH |
Bd Industry Electronic Cable, Halogen-Free, According
to VDE 0816 |
![VDE Approval](../images/approvalpics/small_approvalpics/vde.gif) |
![J-H(St)H (Bd Installation Cable, DIN VDE 0815, Halogen-Free)](../images/continue_arrow_black_red.gif) |
![J-H(St)H Bd Installation cable, halogen-free, according to VDE 0816, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen free Security Cables](../images/cable/halogenfree_security/installation/small/J-H(St)H.jpg) |
J-H(St)H |
Bd Installation Cable, DIN
VDE 0816, Halogen-Free |
![VDE Approval](../images/approvalpics/small_approvalpics/vde.gif) |
![J-H(St)H (Bd Fire Warning Installation Cable, Halogen-Free)](../images/continue_arrow_black_red.gif) |
![J-H(St)H Bd Fire warning installation cable, halogen-free, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/J-H(St)H_fire.jpg) |
J-H(St)H |
Bd Fire Warning Installation Cable, Halogen-Free |
- |
![N2XCH (Power Cable, 0.6/1 kV, Halogen-free, VDE Approved, With Concentric Conductor, Without Functionality)](../images/continue_arrow_black_red.gif) |
![N2XCH power cable, 0.6/1 kV, halogen-free, with concentric conductor, without functionality, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/N2XCH.jpg) |
N2XCH |
Power Cable, 0.6/1 kV, Halogen-free, VDE Approved, With
Concentric Conductor, Without Functionality |
![PCT Approval](../images/approvalpics/small_approvalpics/pct.gif) ![VDE Approval](../images/approvalpics/small_approvalpics/vde.gif) |
![N2XCH-FE 180/E 30 (Installation Security Cable, Halogen-free, 0.6/1 kV, With improved fire characteristics)](../images/continue_arrow_black_red.gif) |
![N2XCH-FE 180/E 30 security cable, halogen-free, 0.6/1 kV, with improved fire characteristics, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/N2XCH-FE_180_E30.jpg) |
N2XCH-FE 180/E 30 |
Installation Security Cable, Halogen-Free,
0.6/1 kV, With Improved Fire Characteristics |
![PCT Approval](../images/approvalpics/small_approvalpics/pct.gif) |
![N2XCH-FE 180/ E 90 (Installation Security Cable, Halogen-free, 0.6/1 kV, With improved fire characteristics)](../images/continue_arrow_black_red.gif) |
![N2XCH-FE 180/E 90 security cable, halogen-free, 0.6/1 kV, with improved fire characteristics, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/N2XCH-FE_180_E90.jpg) |
N2XCH-FE 180/ E 90 |
Installation Security Cable, Halogen-Free,
0.6/1 kV, With Improved Fire Characteristics |
- |
![N2XH (Power Cable, 0.6/1 kV, Halogen-free, VDE Approved, Without Functionality)](../images/continue_arrow_black_red.gif) |
![N2XH power cable, 0.6/1 kV, halogen-free, without functionality, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/N2XH.jpg) |
N2XH |
Power Cable, 0.6/1 kV, Halogen-Free, VDE Approved, Without
Functionality |
![PCT Approval](../images/approvalpics/small_approvalpics/pct.gif) ![VDE Approval](../images/approvalpics/small_approvalpics/vde.gif) |
![N2XH-FE 180/E 30 (Installation Security Cable, Halogen-free, 0.6/1 kV, With improved fire characteristics)](../images/continue_arrow_black_red.gif) |
![N2XH-FE 180/E 30 security cable, halogen-free, 0.6/1 kV, with improved fire characteristics, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/N2XH-180_E30.jpg) |
N2XH-FE 180/E 30 |
Installation Security Cable, Halogen-Free, 0.6/1 kV, With Improved Fire Characteristics |
![PCT Approval](../images/approvalpics/small_approvalpics/pct.gif) |
![N2XH-FE 180/E 90 (Installation Security Cable, Halogen-free, 0.6/1 kV, With improved fire characteristics)](../images/continue_arrow_black_red.gif) |
![N2XH-FE 180/E 90 security cable, halogen-free, 0.6/1 kV, with improved fire characteristics, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/N2XH-FE_180_E90.jpg) |
N2XH-FE 180/E 90 |
Installation Security Cable, Halogen-Free,
0.6/1 kV, With Improved Fire Characteristics |
- |
![NHXCH-FE 180/E 30 (Installation Security Cable, Halogen-free, 0.6/1 kV, With improved fire characteristics)](../images/continue_arrow_black_red.gif) |
![NHXCH-FE 180/E 30 security cable, halogen-free, 0.6/1 kV, with improved fire characteristics, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/NHXCH-FE_180_E30.jpg) |
NHXCH-FE 180/E 30 |
Installation Security Cable, Halogen-Free,
0.6/1 kV, With Improved Fire Characteristics |
![PCT Approval](../images/approvalpics/small_approvalpics/pct.gif) |
![NHXCH-FE 180/E 90 (Installation Security Cable, Halogen-free, 0.6/1 kV, With improved fire characteristics)](../images/continue_arrow_black_red.gif) |
![NHXCH-FE 180/E 90 security cable, halogen-free, 0.6/1 kV, with improved fire characteristics, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/NHXCH-FE_180_E90.jpg) |
NHXCH-FE 180/E 90 |
Installation Security Cable, Halogen-Free,
0.6/1 kV, With Improved Fire Characteristics |
![PCT Approval](../images/approvalpics/small_approvalpics/pct.gif) |
![NHXH-FE 180/E 30 (Installation Security Cable, Halogen-free, 0.6/1 kV, With improved fire characteristics)](../images/continue_arrow_black_red.gif) |
![NHXH-FE 180/E 30 security cable, halogen-free, 0.6/1 kV, with improved fire characteristics, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/NHXH-FE_180_E30.jpg) |
NHXH-FE 180/E 30 |
Installation Security Cable, Halogen-Free,
0.6/1 kV, With Improved Fire Characteristics |
![PCT Approval](../images/approvalpics/small_approvalpics/pct.gif) |
![NHXH-FE 180/E 90 (Installation Security Cable, Halogen-free, 0.6/1 kV, With improved fire characteristics)](../images/continue_arrow_black_red.gif) |
![NHXH-FE 180/E 90 security cable, halogen-free, 0.6/1 kV, with improved fire characteristics, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/installation/small/NHXH-FE_180_E90.jpg) |
NHXH-FE 180/E 90 |
Installation Security Cable, Halogen-Free,
0.6/1 kV, With Improved Fire Characteristics |
![PCT Approval](../images/approvalpics/small_approvalpics/pct.gif) |
![PUR Single Conductor (Cold resistant, Halogen-free)](../images/continue_arrow_black_red.gif) |
![PUR Single Conductor cold resistant, halogen-free, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/control/small/PUR_Single_CORE.jpg) |
PUR Single Conductor |
Cold Resistant, Halogen-Free |
- |
to top
Halogen-free Control Cables: Overview
|
In all locations,
due to damages of large amount of materials
and more of importance to protect human
life and technical equipment against damages
caused by fire and also for technical enquiries
of insurance, the installation of halogen-free
security cables are required.
You will find on the next following pages
the instructions for installation as well
as the test methods and laying indications
of the halogen-free security cables.
|
The
most important advantages:
- No fire propagation at local flame influence
- Functionality for important systems
- No corrosion and damage by released corrosive
gases and vapors
- Protection of human life and valuable materials,
especially for high quality machines, EDP-systems
etc.
- Prevention of heavy and unexpected subsequent
damage
- Low smoke density helps rescue and fire extinguishing
works
|
|
|
Picture |
Type |
Description |
Approvals |
![H05Z-K / H07Z-K (Rubber insulated single conductor, Halogen-free)](../images/continue_arrow_black_red.gif) |
![H05Z-K / H07Z-K rubber insulated single conductor, halogen-free, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/control/H05Z-K_H07Z-K.jpg) |
H05Z-K / H07Z-K |
Rubber Insulated Single Conductor, Halogen-Free |
![Euro](../images/approvalpics/small_approvalpics/euro.gif) |
![JB-500 HMH (Flexible Control cable, Colored conductor, Halogen-Free, Extremely Fire Resistant, Oil Resistant)](../images/continue_arrow_black_red.gif) |
![JB-500 HMH flexible control cable, colored conductor, halogen-free, extremely fire resistant, oil resistant, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/control/jb_500_hmh.jpg) |
JB-500 HMH |
Flexible Control cable, Colored conductor, Halogen-Free,
Extremely Fire Resistant, Oil Resistant |
![Clean Room Certification](../images/approvalpics/small_approvalpics/ipa.gif) |
![JB-500 HMH-C (Flexible Control cable, Colored conductor, Halogen-Free, Shielded, Extremely Fire Resistant, Oil Resistant, EMI preferred type)](../images/continue_arrow_black_red.gif) |
![JB-500 HMH-C, flexible control cable, colored conductor, halogen-free, shielded, extremely fire resistant, oil resistant , EMI preferred type, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/control/jb_500_hmh_c.jpg) |
JB-500 HMH-C |
Flexible Control Cable, Colored Conductor, Halogen-Free,
Shielded, Extremely Fire Resistant, Oil
Resistant, EMI
Preferred Type |
![Clean Room Certification](../images/approvalpics/small_approvalpics/ipa.gif) |
![JZ-500 HMH (Flexible Control cable, Halogen-Free, Extremely Fire Resistant, Oil Resistant)](../images/continue_arrow_black_red.gif) |
![JZ-500 HMH flexible control cable, halogen-free, extremely fire resistant, oil resistant, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/control/JZ-500_HMH.jpg) |
JZ-500 HMH |
Flexible Control Cable, Halogen-Free, Extremely Fire
Resistant, Oil Resistant |
![Clean Room Certification](../images/approvalpics/small_approvalpics/ipa.gif) ![PCT Approval](../images/approvalpics/small_approvalpics/pct.gif) |
![JZ-500 HMH-C (Flexible Control cable, Halogen-Free, Extremely Fire Resistant, Oil Resistant, Copper shielded, EMI preferred type)](../images/continue_arrow_black_red.gif) |
![JZ-500 HMH-C flexible control cable, halogen-free, extremely fire resistant, oil resistant, copper shielded, EMI preferred type, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/control/JZ-500_HMH-C.jpg) |
JZ-500 HMH-C |
Flexible Control Cable, Halogen-Free, Extremely Fire
Resistant, Oil Resistant, Copper Shielded, EMI Preferred Type |
![Clean Room Certification](../images/approvalpics/small_approvalpics/ipa.gif) ![PCT Approval](../images/approvalpics/small_approvalpics/pct.gif) |
![JZ-600 HMH (Flexible Control cable, Halogen-Free, Extremely Fire Resistant, Oil Resistant, 0.6/1 kV)](../images/continue_arrow_black_red.gif) |
![JZ-600 HMH flexible control cable, halogen-free, extremely fire resistant, oil resistant, 0.6/1 kV, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/control/JZ-600_HMH.jpg) |
JZ-600 HMH |
Flexible Control Cable, Halogen-Free, Extremely Fire
Resistant, Oil Resistant, 0.6/1 kV |
- |
![JZ-600 HMH-C (Flexible Control cable, Halogen-Free, Extremely Fire Resistant, Oil Resistant, 0.6/1 kV, Shielded, EMI preferred type)](../images/continue_arrow_black_red.gif) |
![JZ-600 HMH-C flexible control cable, halogen-free, extremely fire resistant, oil resistant, 0.6/1 kV, shielded, EMI preferred type, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/control/JZ-600_HMH-C.jpg) |
JZ-600 HMH-C |
Flexible Control Cable, Halogen-Free, Extremely Fire
Resistant, Oil Resistant, 0.6/1 kV, Shielded, EMI
Preferred Type |
- |
![PUR Single Conductor (Cold resistant, Halogen-free)](../images/continue_arrow_black_red.gif) |
![PUR Single Conductor cold resistant, halogen-free, RoHS Compliant, RoHS Approved, Sealcon, Helukabel, Halogen-free Security Cables](../images/cable/halogenfree_security/control/PUR_Single_CORE.jpg) |
PUR Single Conductor |
Cold Resistant, Halogen-Free |
- |
to top
Halogen-free Data Cables: Overview
|
In all locations,
due to damages of large amount of materials
and more of importance to protect human
life and technical equipment against damages
caused by fire and also for technical enquiries
of insurance, the installation of halogen-free
security cables are required.
You will find on the next following pages
the instructions for installation as well
as the test methods and laying indications
of the halogen-free security cables.
|
The
most important advantages:
- No fire propagation at local flame influence
- Functionality for important systems
- No corrosion and damage by released corrosive
gases and vapors
- Protection of human life and valuable materials,
especially for high quality machines, EDP-systems
etc.
- Prevention of heavy and unexpected subsequent
damage
- Low smoke density helps rescue and fire extinguishing
works
|
|
Cable
Index |
|
|
|
|
|
|
is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry. |
Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands
Threads: PG, NPT, Metric, BSPP Threads
Materials: Nylon, Nickel Plated Brass, PVDF (for chemicals and extreme temperatures) & Stainless Steel,
NEMA 4x and 6 (IP68, IP 69K).
Approvals: RoHS, Deca BDE, UR, UL, CE, CSA, VDE, German Lloyd, etc.
UL f1 (UL 746C) - Suitable for outdoor use with respect to exposure to ultraviolet light, water exposure and immersion in accordance with UL 746C |
Circular Connectors (M16, M23, RJ45, M27 and M40)
Sizes: M16 Signal, M23 Signal & Power, M27 Signal, M40 Power, M12/16 Twintus
Types: Twintus, RJ45 Industrial Ethernet, PoE Fast Ethernet, Push-Pull, Stainless Steel, Over Molded Cordsets, Standard/EMI Ready
Configurations: Signal (3-28 pole) & Power (6 & 8 pole)
Materials: Nickel Plated Brass, Stainless Steel and Aluminum
Approvals: RoHS, Deca BDE, UR, UL, CSA, TÜV, etc.
|
Industrial Enclosures (Plastic & Metal)
Materials: Polycarbonate, ABS (Acryl-Butadiene-Styrene), Aluminum, Steel/Stainless Steel and Polyester.
Types: Gray or Transparent Lids, available with Hinges and Latches, Plain Walls or Knockouts.
Approvals: RoHS, Deca BDE, UL, CSA, TUV and CE.
Modular, Expandable, UV and Impact Resistant, NEMA 4, 4x (IP 66/67). Solar Plus for Photovoltaic applications.
Our Enclosures can be equipped with Strain Relief Fittings, Circular Connectors or Conduit Fittings. Other customization options like cutting & drilling are also available. |
Conduit System
High Pull-Out Resistance, Robust Performance, Long Life Expectancy, Fastest/ Easy installation, No Tools required!
Fittings: Push-In, Turn-to-Seal, Snapclic DUO (Nylon or Nickel Plated Brass), Double-Seal, Flange/Bulkhead
Conduit: Standard and Super Flex Corrugated Conduit
Accessories: Snap-In Mounting Brackets. NEMA 4 (IP 54/65)
Approvals: RoHS, Deca BDE, UR, German Lloyd, CE, etc.
|
Hazardous Location / Explosive Proof Cord Grips, Cable Glands
These fittings are labeled and approved to withstand the required needs of a combustible environment.
Materials: Nylon, Nickel Plated Brass, PVDF (chemical resistant & extreme temperatures), Stainless Steel.
Threads: NPT, Metric & PG. NEMA 4x (IP 67) and 6 (IP 68/69K)
Approvals: RoHS, Deca BDE, UL, CSA, VDE, CE, EEx e, ATEX, German Lloyd, IECEx,
Ex-d/Ex-e, Ex-i
EXIOS - High-end Cable Glands for armored cables in hazardous areas including the latest IECEx and ATEX certifications, for use in Ex-e, Ex-d and Ex-tD areas
|
Thread Adapters, Enlargers, Reducers
Convert, Increase or Decrease your thread size with our newest product line of Adapters, Enlargers and Reducers.
Threads: NPT, Metric and PG.
Materials: Black or Gray Nylon, Nickel Plated Brass, Aluminum, Stainless Steel.
Approvals: RoHS, Deca BDE, CE, EEe x, ATEX, etc.
Hazardous / Explosive proof versions available.
|
Cable Accessories
Locking Nuts:Black & Gray Nylon, Nickel Plated Brass, Zinc Plated Steel, EMI (w/ Cutting Edges)
O-Rings: Buna-N, Viton®, Silicone
Seal Rings: Polyethylene / Fiber-reinforced Plastic
Hole Plugs: Dome, Hex, Nylon, Nickel Plated Brass
Inserts: Standard, Reduced, Multi-Hole, Romex®
Other Accessories: Ratchet & Socket Wrenches, Cable Clamps, etc.
|
|
|