Description & No.
of conductors x cross-section in mm2
Outer
Diameter
mm
Copper
weight
kg/km
Weight
ca. kg/km
AWG
12723
OZ-600 HMH 2X0.5
6.3
9.6
57.0
20
12724
JZ-600 HMH 3G0.5
6.6
14.4
69.0
20
12725
OZ-600 HMH 3X0.5
6.6
14.4
69.0
20
12726
JZ-600 HMH 4G0.5
7.2
19.0
104.0
20
12727
OZ-600 HMH 4X0.5
7.2
19.0
104.0
20
12728
JZ-600 HMH 5G0.5
8.0
24.0
121.0
20
12729
OZ-600 HMH 5X0.5
8.0
24.0
121.0
20
12730
JZ-600 HMH 7G0.5
8.7
33.6
145.0
20
12731
JZ-600 HMH 10G0.5
10.6
48.0
186.0
20
12732
JZ-600 HMH 12G0.5
11.4
58.0
224.0
20
12733
JZ-600 HMH 18G0.5
13.8
86.0
292.0
20
12734
JZ-600 HMH 25G0.5
16.1
120.0
357.0
20
12735
OZ-600 HMH 2X0.75
6.6
14.4
68.0
18
12736
JZ-600 HMH 3G0.75
6.9
21.6
77.0
18
12737
OZ-600 HMH 3X0.75
6.9
21.6
77.0
18
12738
JZ-600 HMH 4G0.75
7.5
29.0
136.0
18
12739
OZ-600 HMH 4X0.75
7.5
29.0
136.0
18
12740
JZ-600 HMH 5G0.75
8.4
36.0
152.0
18
12741
OZ-600 HMH 5X0.75
8.4
36.0
152.0
18
12742
JZ-600 HMH 7G0.75
9.3
50.0
208.0
18
12743
JZ-600 HMH 10G0.75
11.1
72.0
250.0
18
12744
JZ-600 HMH 12G0.75
12.2
86.0
271.0
18
12745
JZ-600 HMH 18G0.75
14.5
130.0
387.0
18
12746
JZ-600 HMH 25G0.75
17.2
180.0
498.0
18
12747
OZ-600 HMH 2X1
7.0
19.2
82.0
17
12748
JZ-600 HMH 3G1
7.4
29.0
99.0
17
12749
OZ-600 HMH 3X1
7.4
29.0
99.0
17
12750
JZ-600 HMH 4G1
8.2
38.4
140.0
17
12751
OZ-600 HMH 4X1
8.2
38.4
140.0
17
12752
JZ-600 HMH 5G1
9.2
48.0
160.0
17
12753
OZ-600 HMH 5X1
9.2
48.0
160.0
17
12754
JZ-600 HMH 7G1
9.9
67.0
217.0
17
12755
JZ-600 HMH 10G1
11.9
96.0
271.0
17
12756
JZ-600 HMH 12G1
13.1
115.0
301.0
17
12757
JZ-600 HMH 18G1
15.7
173.0
417.0
17
12758
JZ-600 HMH 25G1
18.6
240.0
576.0
17
Part-No.
Description & No.
of conductors x cross-section in mm2
Outer
Diameter
mm
Copper
weight
kg/km
Weight
ca. kg/km
AWG
12759
OZ-600 HMH 2X1.5
8.2
29.0
97.0
16
12760
JZ-600 HMH 3G1.5
8.6
43.0
119.0
16
12761
OZ-600 HMH 3X1.5
8.6
43.0
119.0
16
12762
JZ-600 HMH 4G1.5
9.6
58.0
148.0
16
12763
OZ-600 HMH 4X1.5
9.6
58.0
148.0
16
12764
JZ-600 HMH 5G1.5
10.7
72.0
172.0
16
12765
OZ-600 HMH 5X1.5
10.7
72.0
172.0
16
12766
JZ-600 HMH 7G1.5
11.6
101.0
243.0
16
12767
JZ-600 HMH 10G1.5
15.2
144.0
311.0
16
12768
JZ-600 HMH 12G1.5
15.5
173.0
392.0
16
12769
JZ-600 HMH 18G1.5
18.6
259.0
529.0
16
12770
JZ-600 HMH 25G1.5
22.5
360.0
741.0
16
12771
OZ-600 HMH 2X2.5
9.6
48.0
160.0
14
12772
JZ-600 HMH 3G2.5
10.1
72.0
177.0
14
12773
OZ-600 HMH 3X2.5
10.1
72.0
177.0
14
12774
JZ-600 HMH 4G2.5
11.2
96.0
209.0
14
12775
OZ-600 HMH 4X2.5
11.2
96.0
209.0
14
12776
JZ-600 HMH 5G2.5
12.5
120.0
272.0
14
12777
OZ-600 HMH 5X2.5
12.5
120.0
272.0
14
12778
JZ-600 HMH 7G2.5
13.8
168.0
340.0
14
12779
JZ-600 HMH 10G2.5
16.7
288.0
561.0
14
12780
JZ-600 HMH 12G2.5
18.3
432.0
799.0
14
12781
JZ-600 HMH 18G2.5
22.0
480.0
940.0
14
12782
JZ-600 HMH 25G2.5
26.2
600.0
1121.0
14
12783
JZ-600 HMH 3G4
11.7
115.0
255.0
12
12784
JZ-600 HMH 4G4
13.0
154.0
319.0
12
12785
JZ-600 HMH 5G4
14.5
192.0
423.0
12
12786
JZ-600 HMH 3G6
13.1
173.0
380.0
10
12787
JZ-600 HMH 4G6
14.5
230.0
441.0
10
12788
JZ-600 HMH 5G6
16.2
288.0
657.0
10
12789
JZ-600 HMH 3G10
16.5
288.0
668.0
8
12790
JZ-600 HMH 4G10
18.2
384.0
796.0
8
12791
JZ-600 HMH 5G10
20.3
480.0
972.0
8
12792
JZ-600 HMH 3G16
20.1
461.0
832.0
6
12793
JZ-600 HMH 4G16
22.3
614.0
1122.0
6
12794
JZ-600 HMH 5G16
25.0
768.0
1604.0
6
Part-No.
Description & No.
of conductors x cross-section in mm2
Outer
Diameter
mm
Copper
weight
kg/km
Weight
ca. kg/km
AWG
12795
JZ-600 HMH 3G25
24.8
720.0
1457.0
4
12796
JZ-600 HMH 4G25
27.4
960.0
1611.0
4
12797
JZ-600 HMH 5G25
30.5
1200.0
2070.0
4
12798
JZ-600 HMH 3G35
27.1
1008.0
1914.0
2
12799
JZ-600 HMH 4G35
30.0
1344.0
2424.0
2
12800
JZ-600 HMH 5G35
33.3
1680.0
2970.0
2
12801
JZ-600 HMH 4G50
35.8
1920.0
3467.0
1
12802
JZ-600 HMH 4G70
40.9
2688.0
4491.0
2/0
12803
JZ-600 HMH 4G95
46.2
3648.0
6170.0
3/0
12804
JZ-600 HMH 4G120
51.6
4608.0
7618.0
4/0
¹) For the critical applications
we advise for consultation
Technical
Data
Halogen-free, flexible control
cable, conductor construction adapted
to E DIN VDE 0281 part 14 and
DIN VDE 0281 part 13
Temperature Range Flexing
-15°C to
+70°C (+5°F to
+158°F)
Fixed
-40°C to +70°C (-40°F to
+158°F)
Nominal Voltage U0/U
0.6/1 kV
Test Voltage 4000
V
Minimum Bending Radius For permanent bending
Approx. 15x cable Ø
Radiation Resistance up to 100x106 cJ/kg (up
to 100 Mrad)
Approvals
Cable
Construction
Bare copper, fine wire conductor
to DIN VDE 0295 cl. 5, BS 6360 cl.
5 and/or IEC 60228 cl. 5
Halogen-free polymer conductor insulation,
TI6 acc. to E DIN VDE 0281 part 14
Black conductors with continuous white
numbering according to DIN VDE 0293
Green-yellow grounding in the
outer layer (3 conductors and above)
Conductors stranded in layers with optimal
lay-length
Halogen-free polymer jacket, TM7
acc. to E DIN VDE 0281 Part 14
Jacket color black (RAL 9005)
LS0H = Low Smoke
Zero Halogen-Free
Application
Halogen-free,
flame retardant control cables
are used as measuring and
control cables in machine tools,
conveyor belts,
product lines, in plant construction,
air-conditioning and heating systems
as well as in steel production
works. For fixed installation or
for flexing applications, for casual,
not constantly recurring free movement
without forced motion and without
tensile stress for medium mechanical
loads. These cables are suitable
for use in dry, damp and wet environments
and outdoors for installation in,
on and beneath plaster, as well
as in concrete walls except for
direct imbedding in vibrated, compacted
or compressed concrete. EMI = Electromagnetic
Interference
=
The product
is conformed
with
the EC
Low-Voltage
Directive
73/23/EEC
and 93/68/EEC.
Properties
¹) For the critical applications
we advise for consultation
The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Tests
Flame test acc. to VDE 0482 Part 266-2, BS 4066 Part 3 / DIN EN 50266-2 / IEC 60332-3 (as per DIN VDE 0472 Part 804 Test Method C)
Self-extinguishing and flame-resistant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (as per DIN VDE 0472 Part 804 Test Method B)
Corrosiveness of corrosive gases according to VDE 0482, Part 267 / DIN EN 50267-2-2 / IEC 607542 (as per DIN VDE 0472, Part 813)
Halogen-free acc. to VDE 0482, Part 267 / DIN EN 50267-2-1 / IEC 60754-1 (as per DIN VDE 0472, Part 815)
Smoke density according to VDE 0482 Part 1034-1+2 / IEC 61034-1+2 / DIN EN 61034-1+2 / BS 7622 Part 1+2 (equivalent DIN VDE 0472 Part 816)
Note
G = with green-yellow grounding
x = without green-yellow grounding
(OZ)
is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135 FAX: 303-680-5344