Description & No.
of conductors x cross-section in mm2
Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
53180
NHXH-FE 180/E 90 1X16
RM
11.0
154.0
255.0
6
53181
NHXH-FE 180/E 90 1X25
RM
12.5
240.0
375.0
4
53182
NHXH-FE 180/E 90 1X35
RM
13.5
336.0
475.0
2
53183
NHXH-FE 180/E 90 1X50
RM
15.0
480.0
625.0
1
53184
NHXH-FE 180/E 90 1X70
RM
16.5
672.0
855.0
2/0
53185
NHXH-FE 180/E 90 1X95
RM
18.0
912.0
1140.0
3/0
53186
NHXH-FE 180/E 90 1X120
RM
20.5
1152.0
1410.0
4/0
53187
NHXH-FE 180/E 90 1X150
RM
22.5
1440.0
1730.0
300 kcmil
53188
NHXH-FE 180/E 90 1X185 RM
24.5
1776.0
2140.0
350 kcmil
53189
NHXH-FE 180/E 90 1X240 RM
27.0
2304.0
2700.0
500 kcmil
53190
NHXH-FE 180/E 90 1X300 RM
30.0
2880.0
3420.0
600 kcmil
53191
NHXH-FE 180/E 90 1X400 RM
33.5
3840.0
4310.0
750 kcmil
53000
NHXH-FE 180/E 90 3X1.5
RE
14.0
43.0
280.0
16
53001
NHXH-FE 180/E 90 3X2.5
RE
15.0
72.0
330.0
14
53002
NHXH-FE 180/E 90 3X4
RE
16.0
115.0
400.0
12
53003
NHXH-FE 180/E 90 3X6
RE
17.0
173.0
480.0
10
53004
NHXH-FE 180/E 90 3X10
RE
19.0
288.0
650.0
8
53005
NHXH-FE 180/E 90 3X16
RE
21.0
461.0
850.0
6
52990
NHXH-FE 180/E 90 3X25
RM
25.0
720.0
1300.0
4
52991
NHXH-FE 180/E 90 3X35
RM
28.0
1008.0
1700.0
2
52992
NHXH-FE 180/E 90 3X35
/ 16 RM
28.0
1162.0
1850.0
2
52993
NHXH-FE 180/E 90 3X50
/ 25 RM
32.0
1680.0
2500.0
1
52994
NHXH-FE 180/E 90 3X70
/ 35 RM
36.0
2352.0
3350.0
2/0
52995
NHXH-FE 180/E 90 3X95
/ 50 RM
42.0
3216.0
4500.0
3/0
52996
NHXH-FE 180/E 90 3X120
/ 70 RM
45.0
4128.0
5600.0
4/0
52997
NHXH-FE 180/E 90 3X150
/ 70 RM
49.0
4992.0
6700.0
300
kcmil
52998
NHXH-FE 180/E 90 3X185
/ 95 RM
55.0
6240.0
8350.0
350
kcmil
52999
NHXH-FE 180/E 90 3X240
/ 120 RM
63.0
8064.0
10000.0
500
kcmil
53006
NHXH-FE 180/E 90 4X1.5
RE
15.0
58.0
325.0
16
53007
NHXH-FE 180/E 90 4X2.5
RE
16.0
96.0
385.0
14
53008
NHXH-FE 180/E 90 4X4
RE
17.0
154.0
470.0
12
53009
NHXH-FE 180/E 90 4X6
RE
18.0
230.0
580.0
10
53010
NHXH-FE 180/E 90 4X10
RE
20.0
384.0
790.0
8
53011
NHXH-FE 180/E 90 4X16
RE
22.0
614.0
1100.0
6
53012
NHXH-FE 180/E 90 4X25
RM
27.0
960.0
1650.0
4
53013
NHXH-FE 180/E 90 4X35
RM
30.0
1344.0
2150.0
2
53014
NHXH-FE 180/E 90 4X50
RM
34.0
1920.0
2800.0
1
53030
NHXH-FE 180/E 90 4X70
RM
39.0
2688.0
3800.0
2/0
53031
NHXH-FE 180/E 90 4X95
RM
44.0
3648.0
5050.0
3/0
53070
NHXH-FE 180/E 90 4X120
RM
47.0
4608.0
6150.0
4/0
53390
NHXH-FE 180/E 90 4X150
RM
51.2
5760.0
7662.0
4/0
Part-No.
Description & No.
of conductors x cross-section in mm2
Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
53015
NHXH-FE 180/E 90 5X1.5
RE
16.0
72.0
375.0
16
53016
NHXH-FE 180/E 90 5X2.5
RE
17.0
120.0
445.0
14
53017
NHXH-FE 180/E 90 5X4
RE
18.0
192.0
560.0
12
53018
NHXH-FE 180/E 90 5X6
RE
20.0
288.0
690.0
10
53019
NHXH-FE 180/E 90 5X10
RE
22.0
480.0
950.0
8
53020
NHXH-FE 180/E 90 5X16
RM
24.0
768.0
1300.0
6
53021
NHXH-FE 180/E 90 5X25
RM
29.0
1200.0
1980.0
4
53028
NHXH-FE 180/E 90 5X35
RM
33.0
1680.0
2350.0
2
53029
NHXH-FE 180/E 90 5X50
RM
38.0
2500.0
3100.0
1
53022
NHXH-FE 180/E 90 7X1.5
RE
19.0
101.0
560.0
16
53027
NHXH-FE 180/E 90 7X2.5
RE
21.0
168.0
650.0
14
53025
NHXH-FE 180/E 90 10X1.5
RE
23.0
144.0
750.0
16
53026
NHXH-FE 180/E 90 10X2.5
RE
25.0
240.0
910.0
14
53023
NHXH-FE 180/E 90 12X1.5
RE
25.0
173.0
850.0
16
53024
NHXH-FE 180/E 90 12X2.5
RE
26.0
288.0
1000.0
14
Technical
Data
Halogen-free security cable
with improved characteristics
in the case of fire to DIN VDE
0266
Insulation Integrity 180 minutes to DIN VDE
0472 part 814
Functionality 90 minutes to DIN VDE
4102 part 12
Temperature Range -30°C to +70°C (-22°F to +158°F)
Permissible Operating
Temperature at conductor +90°C/+194°F
Nominal Voltage U0/U
0.6/1 kV
Test Voltage 4000
V
Minimum Bending Radius Approx. 12x cable Ø
Radiation Resistance Up to 200x106 cJ/kg
(up to 200 Mrad)
Caloric Load Values See Technical Information
Approvals
FRNC
Cable
Construction
Bare copper conductor, solid
or stranded, to DIN VDE 0295
cl. 1 or cl. 2, BS 6360 cl. 1
or 2, IEC 60228 cl. 1 or cl.
2, HD 383
Double conductor insulation of mica
tape and cross-linked polymer
HI1, to DIN VDE 0207 part 23
Color coding of conductors according
to DIN VDE 0293-308
Each single conductor covering with
flame resistant glass-fiber tape
Conductors stranded in layer
Conductor wrapping with glass-fiber
tape as flame-protection
Outer jacket orange, polyolefin
compound HM4, to DIN VDE 0207
part 24
Tests
Flame test to VDE 0482 part 266-2, BS 4066 part 3 / DIN EN 50266-2 / IEC 60332-3 (equivalent DIN VDE 0472 part 804 test method C)
Corrosiveness of combustion gases according to VDE 0482 part 267 / DIN EN 50267-2-2 / IEC 60754-2 (equivalent DIN VDE 0472 part 813)
Halogen-free according to VDE 0482
part 267 / DIN EN 50267-2-1 / IEC 60754-1 (equivalent
DIN VDE 0472 part 815)
Smoke density according to VDE 0482 part 1034-1+2 / IEC 61034-1+2 / DIN EN 61034-1+2 / BS 7622 part 1+2 (equivalent DIN VDE 0472 part 816)
Insulation integrity under flame propagation
to VDE 0472 part 814 IEC 60331
Burning behavior in fire (functionality)
of the complete cable system to DIN 4102
part 12 (90 minutes)
LS0H = Low Smoke Zero
Halogen-Free
Application
Every place
where in case of fire human life
and material assets are to be protected
and safety consciousness take a
special significance, e.g. in industrial
complexes, power stations, communal
establishment, hotels, airports,
underground railway networks, hospitals
and outpatients clinic (DIN VDE
0107), department stores, data
processing centers, theaters, cinemas,
in multi-story buildings, public
gatherings, schools etc. (DIN VDE
0108), mining works, offshore plants,
leading centers, traffic communication,
emergency power supply and alarm
systems. Suitable for fixed installation
in dry and moist rooms, in, above,
on and beneath plaster as well
as in walls and in concrete.
These cables are suitable for outdoor
applications and in underground
by using in conduits or tubes.
Additionally valid also DIN VDE 0298
part 1 and 2.
For the installation in conduit all
precautions must be taken that no
accumulation of water can occur in
the pipes.
=
The product is conformed with the
EC Low-Voltage Directive 2006/95/EG.
Properties
Halogen-free; no evolution
of corrosive and toxic gases
Flame retardant
Hardly flammable
Self-extinguished and fire
resistant
No flame propagation, therefore
security from fire
Low smoke density, no darkening
of emergency exits without
hindering the fire extinguishing
works
Toxicologically harmless
No self-ignition
Maintenance of functionality
during the increased current
load
FE 180: Insulation
integrity for 180
minutes. Tests to DIN VDE
0472 part 814 IEC 60331. Insulation integrity under
direct flame propagation
for the test period of 180
minutes.
E 90: Functionality of
electrical cable systems for
minimum 90 minutes. Test method
to DIN 4102 part 12. This fulfils
the demands of technical guide
lines for fire protection (supplement
1 to DIN VDE 0108 part 1).
The functionality for
90 minutes assures the functional
performance of water-pressure-rising
stations for the supply to
avoid smoke and heat in safety-stairs
and inner rooms, ladder shafts
and engine rooms for fire brigade
lifts, emergency lifts for
sickbeds in hospitals and the
fire brigade lifts.
Note
RE = round conductor, multiple-wire
RM = round conductor, single-wire
is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135 FAX: 303-680-5344