Radiation resistance up
to 80x106 cJ/kg
(up to 80 Mrad)
Coupling resistance max.
250 Ohm/km
Approvals
Cable
Construction
Bare copper, extra fine wire
conductors to DIN VDE 0295 cl.
6 col. 4, BS 6360 cl. 5 and IEC
60228 cl. 6
Special PVC conductor insulation,
YI8 to DIN VDE 0207 part 4 and
class 43 to UL Std. 1581
Red conductors with continuous white
figure imprint to DIN VDE 0293
Green-yellow grounding in the
outer layer
Conductors with optimal selected lay length
Conductor wrapping with fleece over
each layer
PVC-inner jacket
Shielding: braid coverage ca.
85%
up to 17 mm Ø - layer of
tinned copper wires
> 17 mm Ø - tinned copper
wire
Special PVC outer jacket YM5
to DIN VDE 0207 part 5, UL Style
2587 and CSA C22.2 No 210
Outer jacket: Black (RAL 9005)
Application
These cables
are for flexible use for
medium mechanical stresses
with free movement without
tensile stress or forced movements
in dry, moist and wet rooms.
These special cables for drag
chains are used for permanent
flexible applications in machineries,
machine tools, robot technics, and
for movable automated machinery
parts. These cables have shown
excellent performance in combination
with standard cable trays.
The dense shielding assures
disturbance-free transmission
of all signals and impulses.
An ideal disturbance-free control
cable for the above applications.
Intended for the export-oriented
machines and machinery plants.
For applications which go beyond
standard solutions, we recommend
for our specially developed inquiry sheet for energy guiding
systems. Before installation
in cable trays, please read
the instructions. For further technical
details, see selection table
for drag chain cables and see
lead text. EMI =
Electromagnetic
Interference
To optimize the EMI features
we recommend a large round
contact of the copper braiding
on both ends. RC =
Robotics
Cable
=
The product is conformed
with the EC Low-Voltage
Directive 2006/95/EG.
Properties
PVC self-extinguishing and flame
retardant according to DIN VDE
0482-332-1-2, DIN EN 60332-1-2 /
IEC 60332-1 (equivalent DIN VDE
0472 part 804 test method B)
UV-resistant
The materials used in manufacture
are cadmium-free, contain no
silicone and are free from substances
harmful to the wetting properties
of lacquers
Note
G = with green-yellow grounding
AWG sizes are approximate equivalent
values. The actual cross-section
is in mm².
is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands Threads: PG, NPT, Metric, BSPP Threads Materials: Nylon, Nickel Plated Brass, PVDF (for chemicals and extreme temperatures) & Stainless Steel,
NEMA 4x and 6 (IP68, IP 69K). Approvals: RoHS, Deca BDE, UR, UL, CE, CSA, VDE, German Lloyd, etc. UL f1 (UL 746C) - Suitable for outdoor use with respect to exposure to ultraviolet light, water exposure and immersion in accordance with UL 746C
Circular Connectors (M16, M23, RJ45, M27 and M40) Sizes: M16 Signal, M23 Signal & Power, M27 Signal, M40 Power, M12/16 Twintus Types: Twintus, RJ45 Industrial Ethernet, PoE Fast Ethernet, Push-Pull, Stainless Steel, Over Molded Cordsets, Standard/EMI Ready Configurations: Signal (3-28 pole) & Power (6 & 8 pole) Materials: Nickel Plated Brass, Stainless Steel and Aluminum Approvals: RoHS, Deca BDE, UR, UL, CSA, TÜV, etc.
Industrial Enclosures (Plastic & Metal) Materials: Polycarbonate, ABS (Acryl-Butadiene-Styrene), Aluminum, Steel/Stainless Steel and Polyester. Types: Gray or Transparent Lids, available with Hinges and Latches, Plain Walls or Knockouts. Approvals: RoHS, Deca BDE, UL, CSA, TUV and CE.
Modular, Expandable, UV and Impact Resistant, NEMA 4, 4x (IP 66/67). Solar Plus for Photovoltaic applications.
Our Enclosures can be equipped with Strain Relief Fittings, Circular Connectors or Conduit Fittings. Other customization options like cutting & drilling are also available.
Conduit System
High Pull-Out Resistance, Robust Performance, Long Life Expectancy, Fastest/ Easy installation, No Tools required!
Fittings: Push-In, Turn-to-Seal, Snapclic DUO (Nylon or Nickel Plated Brass), Double-Seal, Flange/Bulkhead
Conduit: Standard and Super Flex Corrugated Conduit Accessories: Snap-In Mounting Brackets. NEMA 4 (IP 54/65) Approvals: RoHS, Deca BDE, UR, German Lloyd, CE, etc.
Hazardous Location / Explosive Proof Cord Grips, Cable Glands
These fittings are labeled and approved to withstand the required needs of a combustible environment. Materials: Nylon, Nickel Plated Brass, PVDF (chemical resistant & extreme temperatures), Stainless Steel. Threads: NPT, Metric & PG. NEMA 4x (IP 67) and 6 (IP 68/69K)
Approvals: RoHS, Deca BDE, UL, CSA, VDE, CE, EEx e, ATEX, German Lloyd, IECEx,
Ex-d/Ex-e, Ex-i EXIOS - High-end Cable Glands for armored cables in hazardous areas including the latest IECEx and ATEX certifications, for use in Ex-e, Ex-d and Ex-tD areas
Thread Adapters, Enlargers, Reducers
Convert, Increase or Decrease your thread size with our newest product line of Adapters, Enlargers and Reducers. Threads: NPT, Metric and PG. Materials: Black or Gray Nylon, Nickel Plated Brass, Aluminum, Stainless Steel. Approvals: RoHS, Deca BDE, CE, EEe x, ATEX, etc.
Hazardous / Explosive proof versions available.