Special polyurethane-jacketed
multi conductor cable on the basis
of E DIN VDE 0245 part 202/03.92
up to 1.5 mm�, on the basis
of E DIN VDE 0281 part 13 as
of 2.5 mm�
Temperature Range Flexing
-5�C to +80�C (+23�F to +176�F)
Fixed Installation
-40�C
to +80�C (-40�F to +176�F)
Nominal Voltage U0/U
300/500 V
As of cross section 4 mm�
U0/U 450/750 V
Radiation Resistance Up to
100x106 cJ/kg
(up to 100 Mrad)
Coupling Resistance Max.
250 Ohm/km
Approvals
Cable
Construction
Plain copper conductor, finely stranded
according to DIN VDE 0295 cl. 5, BS 6360
cl. 5 and IEC 60228 cl. 5
Oil resistant PVC
conductor insulation TI2, adapted to DIN
VDE 0281 part 1, for better sliding abilities
Conductors black with sequential numbering
imprinted in white according to DIN VDE
0293
Green-yellow grounding in the outer
layer (3 conductors and above)
Conductors stranded in layers with optimal
lay-length
Oil resistant PVC
inner jacket
Shield of tinned copper braid, coverage
approx. 85%
Fleece separator, ensures good dismantling
ability
Special full-polyurethane outer
jacket TMPU, to DIN VDE 0282 part 10,
appendix A
Jacket color: Gray (RAL 7001)
Application
Extremely robust
control cable characterized by
high abrasion and notch resistance
properties. Used for critical areas
in such applications as machinery,
tooling and plant construction,
in rolling mills and steel works
particularily because of the resistance to mineral
oils and to coolant emulsions. The mechanical strength
of the cable is increased by the
additional oil-resistant inner
jacket. The ideal interference-protected
control cable for such applications
as given above. Suitable for outdoor
installation.
These shielded cables are particularly
suitable for the interference-free
transmission in instrumentation and
control engineering applications. EMI =
Electromagnetic Interference
To optimize the EMI features we recommend
a large round contact of the copper
braiding on both ends.
=
The product is conformed
with the EC Low-Voltage
Directive 73/23/EEC
and 93/68/EEC.
Properties
Resistant to: UV-radiation,
oxygen, ozone and hydrolysis, microbes
Self-extinguishing and flame retardant
according to DIN VDE 0482-332-1-2 / DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Note
G = with green-yellow grounding
X = without green-yellow grounding (OZ)
AWG sizes are approximate equivalent
sizes. The actual cross-section is in mm2.
is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands Threads: PG, NPT, Metric, BSPP Threads Materials: Nylon, Nickel Plated Brass, PVDF (for chemicals and extreme temperatures) & Stainless Steel,
NEMA 4x and 6 (IP68, IP 69K). Approvals: RoHS, Deca BDE, UR, UL, CE, CSA, VDE, German Lloyd, etc. UL f1 (UL 746C) - Suitable for outdoor use with respect to exposure to ultraviolet light, water exposure and immersion in accordance with UL 746C
Circular Connectors (M16, M23, RJ45, M27 and M40) Sizes: M16 Signal, M23 Signal & Power, M27 Signal, M40 Power, M12/16 Twintus Types: Twintus, RJ45 Industrial Ethernet, PoE Fast Ethernet, Push-Pull, Stainless Steel, Over Molded Cordsets, Standard/EMI Ready Configurations: Signal (3-28 pole) & Power (6 & 8 pole) Materials: Nickel Plated Brass, Stainless Steel and Aluminum Approvals: RoHS, Deca BDE, UR, UL, CSA, TÜV, etc.
Industrial Enclosures (Plastic & Metal) Materials: Polycarbonate, ABS (Acryl-Butadiene-Styrene), Aluminum, Steel/Stainless Steel and Polyester. Types: Gray or Transparent Lids, available with Hinges and Latches, Plain Walls or Knockouts. Approvals: RoHS, Deca BDE, UL, CSA, TUV and CE.
Modular, Expandable, UV and Impact Resistant, NEMA 4, 4x (IP 66/67). Solar Plus for Photovoltaic applications.
Our Enclosures can be equipped with Strain Relief Fittings, Circular Connectors or Conduit Fittings. Other customization options like cutting & drilling are also available.
Conduit System
High Pull-Out Resistance, Robust Performance, Long Life Expectancy, Fastest/ Easy installation, No Tools required!
Fittings: Push-In, Turn-to-Seal, Snapclic DUO (Nylon or Nickel Plated Brass), Double-Seal, Flange/Bulkhead
Conduit: Standard and Super Flex Corrugated Conduit Accessories: Snap-In Mounting Brackets. NEMA 4 (IP 54/65) Approvals: RoHS, Deca BDE, UR, German Lloyd, CE, etc.
Hazardous Location / Explosive Proof Cord Grips, Cable Glands
These fittings are labeled and approved to withstand the required needs of a combustible environment. Materials: Nylon, Nickel Plated Brass, PVDF (chemical resistant & extreme temperatures), Stainless Steel. Threads: NPT, Metric & PG. NEMA 4x (IP 67) and 6 (IP 68/69K)
Approvals: RoHS, Deca BDE, UL, CSA, VDE, CE, EEx e, ATEX, German Lloyd, IECEx,
Ex-d/Ex-e, Ex-i EXIOS - High-end Cable Glands for armored cables in hazardous areas including the latest IECEx and ATEX certifications, for use in Ex-e, Ex-d and Ex-tD areas
Thread Adapters, Enlargers, Reducers
Convert, Increase or Decrease your thread size with our newest product line of Adapters, Enlargers and Reducers. Threads: NPT, Metric and PG. Materials: Black or Gray Nylon, Nickel Plated Brass, Aluminum, Stainless Steel. Approvals: RoHS, Deca BDE, CE, EEe x, ATEX, etc.
Hazardous / Explosive proof versions available.