We can also
have your company name printed on these cables.
Technical
Data
European
Special cables corresponding
to DIN VDE 0250 and 0282 part
810
Temperature Range -40°C to +80°C
(-40°F to 176°F)
(max. temperature for the outer
surface)
Permissible Operating
Temperature at conductor +90°C/+194°F
Nominal Voltage U0/U
450/750 V
Operating Voltage
For
alternating and three-phase
currents
U0/U 413/825
V
For direct currents
U0/U 619/1238
V
Current Rating to
DIN 57100 part 523/ VDE 0100
part 523
Test Voltage 15
min 2.5 kV
Max. permitted Tensile
Stress Per mm² conductor
15 N
Minimum Bending Radius
Flexing Up to 8 mm conductor Ø min.
3x conductor Ø
Above 8 mm to 12 mm conductor Ø
min. 4x conductor Ø
Above 12 mm conductor Ø min.
5x conductor Ø Fixed Installation Up to 12 mm conductor Ø min.
3x conductor Ø
Above 12 mm conductor Ø min.
4x conductor Ø
Temperature Limit
In water: max. +40°C/104°F,
max. +60°C/+140°F
with limited duration of life In air:
Flexible
-50°C to +80°C (-50°F to +176°F)
Stationary
-30°C to +80°C (-22°F to +176°F)
Approvals
Cable
Construction
Bare copper, fine wire conductors
bunch stranded to DIN VDE 0295
cl. 5, BS 6360 cl. 5 and IEC 60228
cl. 5
Foil as separator
EPR conductor insulation, compound
type 3GI3 to DIN VDE 0207 part
20
Color code according to DIN
VDE 0293
Conductors stranded in layers with
optimal lay-length
EPR outer jacket, blue, compound
type 5GM3 adapted to DIN VDE 0207
part 21
Application
Tauchflex-R
is a special cable for use as a
connecting and control cable for
submersible motor pumps, underwater
floodlights, floating switch and
has proven its worth for constant
use in waste water or water for
general use up to the depth of
immersion of 500 m (50 bar) and
under temperatures of up to 70°C/+158°F.
Tauchflex-R can also be installed
for use in dry, damp and humid areas
as well as in the open air.
Not suitable for the installation
in hazardous areas.
=
The product
is conformed
with
the EC
Low-Voltage
Directive
2006/95/EG.
Properties
Good insulation properties when
submerged in water
Minimal weight gain under water
The mechanical stability of the
insulation materials remain constant
even when submerged
Not suitable for drinking water
Cables for use in drinking water
with BAM- certificate on request
(BAM
= Bundesanstalt für Materialprüfung
/ Federal Institute for Material
Testing)
Installation adaptability for machinery
materials of protection class II
As rotor-connection cable for motors
up to 1000 V with protected fixed
installation in tubes
Note
G = with green-yellow ground conductor
x = without green-yellow ground conductor
AWG sizes are approximate equivalent
values. The actual cross-section is
in mm².
Please note: halogen-free
types available on request
is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135 FAX: 303-680-5344