HOME 

Pre-assembled Cable: PUR Connecting Cables, orange


Sealcon, Inc, European & Domestic cable

PUR Connecting Cables, orange, Pre-assembled Cables, Sealcon, European
Technical Data  
  • Temperature range
    -40°C to +90°C
  • Nominal voltage
    H05BQ-F 300/500 V
    H07BQ-F 450/750 V
  • Test voltage 3000 V
  • End 1: Plug
  • End 2: 30 mm stripped with wire end ferrule
 
Part-No. Cable Type, cross-sec. mm2 Length (m) Plug Type Copper Weight
kg/1000 pcs.
AWG
84656  H05BQ-F 2x0.75 2 Central Contour Connector 28.8 18
84657  H05BQ-F 2x0.75 5 Central Contour Connector 72.0 18
87802  H05BQ-F 2x0.75 3 Central Contour Connector 43.2 18
84658  H05BQ-F 2x0.75 10 Central Contour Connector 144.0 18
84666  H05BQ-F 2x1 10 Central Contour Connector 192.0 17
84664  H05BQ-F 2x1 3 Central Contour Connector 57.6 17
84663  H05BQ-F 2x1 2 Central Contour Connector 3.4 17
84665  H05BQ-F 2x1 5 Central Contour Connector 96.0 17
84671  H07BQ-F 2x1.5 10 Central Contour Connector 290.0 16
84669  H07BQ-F 2x1.5 2 Central Contour Connector 58.0 16
84670  H07BQ-F 2x1.5 3 Central Contour Connector 87.0 16
86989  H07BQ-F 2x1.5 5 Central Contour Connector 145.0 16
84662  H05BQ-F 3G0.75 10 Protected Plug, straight 216.0 18
84660  H05BQ-F 3G0.75 3 Protected Plug, straight 64.8 18
84661  H05BQ-F 3G0.75 5 Protected Plug, straight 108.0 18
84659  H05BQ-F 3G0.75 2 Protected Plug, straight 43.2 18
84668  H05BQ-F 3G1 10 Protected Plug, straight 290.0 17
86775  H05BQ-F 3G1 3 Protected Plug, straight 87.0 17
86774  H05BQ-F 3G1 5 Protected Plug, straight 145.0 17
84667  H05BQ-F 3G1 2 Protected Plug, straight 58.0 17
84673  H07BQ-F 3G1.5 10 Protected Plug, straight 430.0 16
87548  H07BQ-F 3G1.5 5 Protected Plug, straight 215.0 16
86782  H07BQ-F 3G1.5 3 Protected Plug, straight 129.0 16
84672  H07BQ-F 3G1.5 2 Protected Plug, straight 86.0 16
 
Cable Construction  
  • Tinned copper conductor, fine wire stranded
  • Rubber conductor insulation
  • conductors stranded
  • conductors color coded to VDE 0293
  • PUR outer jacket orange with VDE marking
Properties  
  • Plugs: Central contour connector or Protected plug (straight)
Note  
  • G = with green-yellow grounding, x = without grounding
  • AWG sizes are approximate equivalent values. The actual cross-section is in mm².
Application
These robust special rubber sheathed cables can be used where high demands are placed on temperature range, flexibility and mechanical stress. For application on construction sites, in steel works and rolling mills in heating and air-conditioning systems, in the bottling industry, in machinery and plant construction, in the chemical industry and painting systems, as well as for the professional and the hobby enthusiast. The choice of yellow as the jacket color ensures additional safety. Can be used in potentially explosive areas acc. to DIN VDE 0165.
CE Approval = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.

Toll Free: 800-456-9012 / 303-699-1135 Fax: 303-680-5344
7374 S Eagle Street
Centennial, CO 80112-4240 USA
© 2017 Sealcon

Valid XHTML 1.0 Transitional