Pre-assembled Cable: PUR Connecting Cables, orange
Sealcon, Inc, European & Domestic cable |
|
|
|
- Temperature range
-40°C to +90°C
- Nominal voltage
H05BQ-F 300/500 V
H07BQ-F 450/750 V
|
- Test voltage 3000 V
- End 1: Plug
- End 2: 30 mm stripped with wire end ferrule
|
|
|
|
|
Part-No. |
Cable
Type, cross-sec. mm2 |
Length
(m) |
Plug
Type |
Copper
Weight
kg/1000 pcs. |
AWG |
84656 |
H05BQ-F
2x0.75 |
2 |
Central Contour
Connector |
28.8 |
18 |
84657 |
H05BQ-F
2x0.75 |
5 |
Central Contour
Connector |
72.0 |
18 |
87802 |
H05BQ-F
2x0.75 |
3 |
Central Contour
Connector |
43.2 |
18 |
84658 |
H05BQ-F
2x0.75 |
10 |
Central Contour
Connector |
144.0 |
18 |
84666 |
H05BQ-F
2x1 |
10 |
Central Contour
Connector |
192.0 |
17 |
84664 |
H05BQ-F
2x1 |
3 |
Central Contour
Connector |
57.6 |
17 |
84663 |
H05BQ-F
2x1 |
2 |
Central Contour
Connector |
3.4 |
17 |
84665 |
H05BQ-F
2x1 |
5 |
Central Contour
Connector |
96.0 |
17 |
84671 |
H07BQ-F
2x1.5 |
10 |
Central Contour
Connector |
290.0 |
16 |
84669 |
H07BQ-F
2x1.5 |
2 |
Central Contour
Connector |
58.0 |
16 |
84670 |
H07BQ-F
2x1.5 |
3 |
Central Contour
Connector |
87.0 |
16 |
86989 |
H07BQ-F
2x1.5 |
5 |
Central Contour
Connector |
145.0 |
16 |
84662 |
H05BQ-F
3G0.75 |
10 |
Protected
Plug, straight |
216.0 |
18 |
84660 |
H05BQ-F
3G0.75 |
3 |
Protected
Plug, straight |
64.8 |
18 |
84661 |
H05BQ-F
3G0.75 |
5 |
Protected
Plug, straight |
108.0 |
18 |
84659 |
H05BQ-F
3G0.75 |
2 |
Protected
Plug, straight |
43.2 |
18 |
84668 |
H05BQ-F
3G1 |
10 |
Protected
Plug, straight |
290.0 |
17 |
86775 |
H05BQ-F
3G1 |
3 |
Protected
Plug, straight |
87.0 |
17 |
86774 |
H05BQ-F
3G1 |
5 |
Protected
Plug, straight |
145.0 |
17 |
84667 |
H05BQ-F
3G1 |
2 |
Protected
Plug, straight |
58.0 |
17 |
84673 |
H07BQ-F
3G1.5 |
10 |
Protected
Plug, straight |
430.0 |
16 |
87548 |
H07BQ-F
3G1.5 |
5 |
Protected
Plug, straight |
215.0 |
16 |
86782 |
H07BQ-F
3G1.5 |
3 |
Protected
Plug, straight |
129.0 |
16 |
84672 |
H07BQ-F
3G1.5 |
2 |
Protected
Plug, straight |
86.0 |
16 |
|
|
|
|
- Tinned copper conductor, fine wire stranded
- Rubber conductor insulation
- conductors stranded
- conductors color coded to VDE 0293
- PUR outer jacket orange with VDE marking
|
|
|
- Plugs: Central contour connector or Protected plug (straight)
|
|
|
- G = with green-yellow grounding, x = without grounding
- AWG sizes are approximate equivalent values. The actual cross-section is in mm².
|
|
These robust special rubber sheathed cables can be used where high demands are placed on temperature range, flexibility and mechanical stress. For application on construction sites, in steel works and rolling mills in heating and air-conditioning systems, in the bottling industry, in machinery and plant construction, in the chemical industry and painting systems, as well as for the professional and the hobby enthusiast. The choice of yellow as the jacket color ensures additional safety. Can be used in potentially explosive areas acc. to DIN VDE 0165.
= The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC. |
|
|
|
|
|