Power Cable, 0.6/1 kV, VDE Approved, with Concentric Copper Conductor
Sealcon, Inc, European & Domestic cable
European Part-No.
Description & No.
Conductors x cross-sec. mm2
Outer
Diameter
mm
Copper
Weight
kg/km
Aluminum
Weight
kg/km
Weight
ca. kg/km
AWG
32840
NAYCWY 4 X 16 re / 16
21.5
182.0
186.0
1250.0
6
32841
NAYCWY 4 X 25 re / 16
25.0
182.0
290.0
1800.0
4
32842
NAYCWY 4 X 35 sm / 16
27.1
182.0
406.0
2050.0
2
32843
NAYCWY 4 X 50 sm / 25
28.2
283.0
580.0
2700.0
1
32844
NAYCWY 4 X 70 sm / 35
32.3
394.0
814.0
3750.0
2/0
32845
NAYCWY 4 X 95 sm / 95
35.8
560.0
1102.0
5000.0
3/0
32846
NAYCWY 4 X 120 sm / 70
39.2
780.0
1392.0
6350.0
4/0
32847
NAYCWY 4 X 150 sm / 70
43.2
780.0
1740.0
7650.0
300 kcmil
32848
NAYCWY 4 X 185 sm / 95
48.4
1056.0
2146.0
9350.0
350 kcmil
32849
NAYCWY 4 X 240 sm / 120
56.0
1130.0
2784.0
11600.0
500 kcmil
Technical
Data
European
Power and control cable
to DIN VDE 0276 part 603,
HD 603 S1 and IEC 60502
Temperature
Range Flexing
-5°C
to +50°C (+23°F
to +122°F)
Fixed Installation
-40°C
to +70°C (-40°F
to +158°F)
Permissible Operating Temperature
at conductor +70°C/+158°F
Permissible Short Circuit Temperature
+160°C/+320°F (short circuit duration 5 sec.)
Nominal Voltage U0/U
0.6/1 kV
Test Voltage 4
kV
Max. permissible Tensile
Stress with cable grip
for copper conductor
= 50 N/mm²
Minimum Bending
Radius Approx. 12x cable ø
Power Ratings See Technical
Information
Caloric Load
Values See Technical
Information
Approvals
Cable
Construction
Aluminium conductor according to DIN VDE 0295 cl. 1, IEC 60228, BS 6360 cl. 1 or HD 383
16-25 mm² round conductor
single wire (re) or 35-240 mm²
sector shaped conductor, multi-wire (sm)
PVC conductor insulation, DIV4 to HD 603.1
Colour coded to DIN VDE 0293-308 and HD 186
Cores stranded concentrically
Filling compound
Concentric conductor (Ceander),
inner layer of corrugated copper
wires, outer layer with copper
tape
PVC outer jacket, DMV5 to HD
603.1
Jacket color: Black
Application
Power distribution cables, preferably used for underground installation, primarily in local networks, for industrial applications and switching systems, power stations. Wherever increased electrical and mechanical protection are required. Installation in water, outdoors, in concrete, indoors and in cable ducts. The concentric conductor (C) can be used as a PE or PEN conductor or as a shield. The corrugated design (Ceander) of the concentric conductor permits any number of cable junctions during assembly, without any conductors having to be cut. This ensures a optimal reliability.
=
The
product
is
conformed
with
the
EC
Low-Voltage
Directive
2006/95/EG.
Properties
PVC self-extinguishing and
flame retardant according to
VDE 0482-332-1-2, DIN EN
60332-1-2 / IEC 60332-1 (equivalent
DIN VDE 0472 part 804 test method
B)
The materials used in manufacture
are cadmium-free, contain no
silicone and are free from substances
harmful to the wetting properties
of lacquers
Highest
permissible voltage
Direct
current systems 1.8 kV
Alternating current systems
single-phase systems
Both conductors insulated 1,4 kV
single-phase systems
One conductor grounded 0,7 kV
Three-phase systems 1,2 kV
With concentric conductor and
a cross-section from 240 mm² 3,6 kV
Note
rm =
round conductor, single-wire; sm =
sector-shaped conductor, multi-wire.
is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135 FAX: 303-680-5344