PDF Printable PDF

Data, Network
& BUS Cable: HF-Radiating Cables HF FRNC

   

Sealcon, Inc, European & Domestic cable

HF-Radiating Cables, HF FRNC, Sealcon, , RoHS Approved, RoHS Compliant
Part-No. Designation Nominal Size Outer
Dia. mm
Weight kg/km 1 km system loss (dB) 120 dB-length (m)
450 900 1800 2200 2400 450 900 1800 2200 2400
(MHz) (MHz)
Corrugations, groups of apertures at large intervals
800227 HALFU 12-50 1/2" 15.0 290.0 129 155 195 210 216 830 560 350 310 295
800228 HRLF 58-50 5/8" 22.0 380.0 113 133 - - - 1300 900 - - -
800229 HRLF 78-50 7/8" 28.7 620.0 93 110 - - - 1965 1220 - - -
800230 HRLFW 78-50 7/8" 28.7 620.0 100 114 150 - - 1750 1150 650 - -
800231 HRLF 114-50 1 1/4" 38.8 920.0 86 103 - - - 2580 1450 - - -
800232 HRLFW 114-50 1 1/4" 38.8 920.0 90 100 144 - - 2500 1630 710 - -
800233 HRLFW 158-50 1 5/8" 48.0 1200.0 92 97 120 - - 2650 1850 1000 - -

Corrugations, groups of vertical slots at short intervals
800234 HRLKW 12-50 1/2" 15.0 290.0 124 154 274 - - 930 625 300 - -
800235 HRLKU 12-50 1/2" 15.0 290.0 126 160 289 324 349 900 600 270 235 220
800236 HRLKW 58-50 5/8" 22.0 380.0 107 127 168 - - 1340 930 570 - -
800237 HRLKU 58-50 5/8" 22.0 380.0 110 125 177 197 208 1265 915 490 425 400
800238 HRLKW 78-50 7/8" 28.7 620.0 95 115 262 - - 1780 1090 320 - -
800239 HRLKU 78-50 7/8" 28.7 620.0 101 113 166 190 212 1650 1135 560 460 395
800240 HRLKW 114-50 1 1/4" 38.8 920.0 90 103 163 - - 2300 1440 610 - -
800241 HRLKU 114-50 1 1/4" 38.8 920.0 96 101 125 145 156 2115 1550 925 695 615
800242 HRLKU 158-50 1 5/8" 48.0 1200.0 101 95 113 123 133 2150 1900 1150 950 820

Corrugations, groups of vertical slots at variable intervals
800243 HRLV 114-50 1 1/4" 38.8 920.0 96 89 - - - - - - - -
800244 HRLVW 114-50 1 1/4" 38.8 920.0 84 86 122 - - - - - - -
800245 HRLVU 158-50 1 5/8" 48.0 1200.0 99 82 95 97 102 - - - - -

Part-No. Designation Nominal Size Outer
Dia. mm
Weight kg/km 1 km system loss (dB) 120 dB-length (m)
450 900 1800 2200 2400 450 900 1800 2200 2400
(MHz) (MHz)
Corrugations, groups of apertures, sloping slots
800246 HRAY 58-50 5/8" 22.0 400.0 103 134 - - - 1440 810 - - -
800247 HRAY 78-50 7/8" 28.7 640.0 95 129 - - - 1760 870 - - -
800248 HRAY 114-50 1 1/4" 38.8 980.0 87 103 - - - 2570 1380 - - -
800249 HRAY 158-50 1 5/8" 48.0 1200.0 108 106 120 132 157 1670 1500 1000 815 600

Corrugations, groups of milled slots
800250 HRCF 38-50 3/8" 12.0 130.0 159 196 259 - - 540 395 250 - -
800251 HRCF 12-50 1/2" 16.0 230.0 124 151 202 225 238 930 630 390 290 240
800252 HRCF 78-50 7/8" 28.0 570.0 105 122 155 166 169 1460 960 600 530 515
800253 HRCF 114-50 1 1/4" 40.0 950.0 102 113 134 148 153 1715 1180 775 605 555
800254 HRCF 158-50 1 5/8" 51.0 1350.0 100 109 122 137 143 2030 1365 960 680 605
Technical Data
  • Not Available

Approvals
RoHS
Cable Construction  
The coax construction is identical for all sizes: inner conductor, foamed dielectric, outer conductor, outer jacket black. This assures the same connector plugs and clamps can always be used. The only difference between the various variants is the form of the opening of the outer conductor. These forms determine the relationship between the inner and outer conductors. Electrical characteristics, such as attenuation, coupling loss, reflection factor as well as environmental conditions (such as dust, salt, moisture, etc.) are influenced in this way. The optimum cable can then be determined from the knowledge of these parameters and the application data (reach, frequency range etc.). The technical differences can be seen from the data for the system loss and the 120 dB length. The outer jacket material is made of a black halogen-free and flame-resistant compound.
Application  
Radiating coax cables permit communication in areas where electromagnetic propagation is impeded, undesirable, or impossible. This may be the case in tunnels, mines, buildings along railway routes and lines, as well as in large building complexes, such as exhibition centers and airports.
Properties  
  • Not Available
Note  
  • Not Available
Cable Accessories  
  • Coming Soon!
Cable Technical Data Construction and ApplicationProperties and Note Accessories
quote
Items For Quote

   
quote
box
Sealcon is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135 FAX: 303-680-5344
Valid XHTML 1.0 Transitional
To Top of Page Top of Page

Copyright © Sealcon All Rights Reserved
|Domestic & International Cables|Enclosures |Liquid Tight Strain Relief Fittings & Accessories|
|Circular Connectors|Conduit System|Pneumatics|Cable Index|Enclosure Index|Search|
|Media|Site Map|Company Overview|Contact|Privacy Policy|Copyright Notice|