Part-No.
Description
Fibers
No.
of Fibers/ Conductor
Outer Ø (mm)
Max.
Tensile Force
Min.
Stat. Bending Radius
Caloric
Load MJ/m
Transverse
Pressure N/cm (max.)
Weight
kg/km
No.
Type
80743
I-V(ZN)HH
2
Multi-Mode
G50/125
1
7.1
1000
270.0
1.00
300
40.0
80799
I-V(ZN)HH
2
Multi-Mode
G62.5/125
1
7.1
1000
270.0
1.00
300
40.0
80813
I-V(ZN)HH
2
Single-Mode
E9/125
1
7.1
1000
270.0
1.00
300
40.0
80753
I-V(ZN)HH
4
Multi-Mode
G50/125
1
7.1
1000
270.0
1.00
300
45.0
80800
I-V(ZN)HH
4
Multi-Mode
G62.5/125
1
7.1
1000
2700.0
1.25
300
45.0
80814
I-V(ZN)HH
4
Single-Mode
E9/125
1
7.1
1000
270.0
1.00
300
45.0
80754
I-V(ZN)HH
6
Multi-Mode
G50/125
1
8.4
1350
270.0
1.25
300
70.0
80769
I-V(ZN)HH
6
Multi-Mode
G62.5/125
1
8.4
1350
270.0
1.25
300
70.0
80815
I-V(ZN)HH
6
Single-Mode
E9/125
1
8.4
1350
270.0
1.25
300
70.0
80688
I-V(ZN)HH
8
Multi-Mode
G50/125
1
9.3
1500
270.0
1.50
300
100.0
80801
I-V(ZN)HH
8
Multi-Mode
G62.5/125
1
9.3
1500
270.0
1.50
300
100.0
80816
I-V(ZN)HH
8
Single-Mode
E9/125
1
9.3
1500
270.0
1.50
300
100.0
80795
I-V(ZN)HH
12
Multi-Mode
G50/125
1
9.6
2350
270.0
1.85
300
165.0
80803
I-V(ZN)HH
12
Multi-Mode
G62.5/125
1
9.6
2350
270.0
1.85
300
165.0
80818
I-V(ZN)HH
12
Single-Mode
E9/125
1
9.6
2350
270.0
1.85
300
165.0
80796
I-V(ZN)HH
16
Multi-Mode
G50/125
1
15.0
2400
270.0
2.40
300
170.0
80804
I-V(ZN)HH
16
Multi-Mode
G62.5/125
1
15.0
2400
270.0
2.40
300
170.0
80819
I-V(ZN)HH
16
Single-Mode
E9/125
1
15.0
2400
270.0
2.40
300
170.0
80798
I-V(ZN)HH
24
Multi-Mode
G50/125
1
17.5
2400
330.0
3.20
300
220.0
80806
I-V(ZN)HH
24
Multi-Mode
G62.5/125
1
17.5
2400
330.0
3.20
300
220.0
80821
I-V(ZN)HH
24
Single-Mode
E9/125
1
17.5
2400
320.0
3.20
300
220.0
Corrosiveness acc. to EN 50267-2-3
Halogen-free acc. to 60754-2
Flame-resistance acc. to IEC 60332-1
Smoke Density acc. to IEC 61034
Fiber
Specifications
Granded
Index Fibers (Multi-Mode)
Specification
Fiber
Type G 50/125
Fiber
Type G 62.5/125
Fiber Category
OM2 Standard
Fiber
OM1 Standard
Fiber
Conductor Diameter
50 ± 3 µm
62.5 ± 3 µm
Numerical Aperture
0.200 ± 0.015
0.275 ± 0.015
Typical
Attenuation
850
nm
2.8 dB/km
3.0 dB/km
1300 nm
0.7 dB/km
1.0 dB/km
Minimum Bandwidth
850 nm
500 MHz x
km
200 MHz x
km
1300 nm
800 MHz x
km
500 MHz x
km
Cladding Diameter
125 ± 1.0 µm
Primary Coating
Diameter
245 ± 10 µm
Conductor Non-circularity
< 5%
Cladding Concentricity
Error
< 3.0 µm
Cladding Non-circularity
< 2%
Specification
Fiber
Type G 50/125
Fiber Category
OM3
Standard Fiber
OM4 Standardfibre
Conductor Diameter
50 ± 3 µm
50 ± 3 µm
Numerical Aperture
0.200 ± 0.015
0.200 ± 0.015
Typical Attenuation
850 nm
2.5
dB/km
3.0
dB/km
1300 nm
0.5
dB/km
1.0 dB/km
Minimum Bandwidth
850 nm
1500
MHz x km
3500 MHz x km
1300 nm
500
MHz x km
500 MHz x km
Cladding Diameter
125 ± 1.0 µm
125 ± 1.0 µm
Primary Coating
Diameter
245 ± 10 µm
245 ± 10 µm
Conductor Non-circularity
< 5%
< 5%
Cladding Concentricity
Error
< 3.0 µm
< 6.0 µm
Cladding Non-circularity
< 2%
< 2%
Single-Mode
Fiber
Specification
Fiber
Type E9...10/125 (single mode)
Fiber Category
ITU-T G.
652
Attenuation
1300
nm
0.36 dB/km
1550 nm
0.22 dB/km
Dispersion
1285 - 1330
nm
< 3.5
ps (nm x km)
1550 nm
< 19 ps
(nm x km)
Wave Length
1312 nm
Mode Field Diameter
at 1310 nm
9.3 ± 0.5 µm
Cladding Diameter
125 ± 1.0 µm
Primary Coating
Diameter
245 ± 10 µm
Cut-off Wave
Length
< 1250
nm
Cladding Concentricity
Error
≤ 0.8 µm
Cladding Non-circularity
< 1.0%
POF and HCS
Fiber
Specification
Fiber
Type POF P980/1000
Fiber
Type HCS K200/230
Conductor Diameter
980 µm
200 µm
Numerical Aperture
0.5
0.37
Typical Attenuation
650 nm
160 dB/km
10 dB/km
850 nm
-
8 dB/km
Minimum Bandwidth
650 nm
10 MHz x
100 m
17 MHz x
km
850 nm
-
20 MHz x
km
Wall Thickness
1000 µm
230 µm
Cable
Construction
Temperature
Range
Conductor
Type:
Tight
Buffer
Strain Relief Elements:
Aramide
Outer Jacket Material:
FRNC
Outer Jacket Color:
Yellow
Laying,
min.:
-5°C/+23°F
Laying,
max:
+50°C/+122°F
Operating,
min.:
-20°C/+68°F
Operating,
max.:
+60°C/+140°F
® breakout
cables are designed to replace splicing
on-site. They are mainly used in
indoor applications for small and
medium transmission lines. The fiber-optic
connectors are be mounted directly
to the individual cables. Therefore
no splicing and no splice boxes are
necessary. Pre-assembled cables only
need to be laid on site and are immediately
functional.
Items For Quote
Update Easy Quote
Data, Network & BUS Cables: Fiber Optic Cables
Fiber Optic Wiring Cables
PATCH
CORD I-VH, I-V11Y, I-VHH,
I-V11Y11Y
INDUSTRY
HCS, I-VH, I-VHH
FIBER
OPTIC BREAKOUT CABLES I-V(ZN)HH
FIBER
OPTIC MINI BREAKOUT CABLES I-V(ZN)H
FIBER
OPTIC BUFFERED FIBER INDOOR CABLES I-D(ZN)H
FIBER
OPTIC UNIVERSAL MINI BREAKOUT CABLES A/I-VQ(ZN)BH
FIBER
OPTIC UNIVERSAL BUFFERED FIBER CABLES A/I-DQ(ZN)BH
/ A/I-D(ZN)BH
FIBER
OPTIC CABLES WITH FUNCTIONAL INTEGRITY A/I-DQ(ZN)BH
FIBER
OPTIC OUTDOOR BUFFERED FIBER CABLES (MINI)
A-D(ZN)2Y / A-D(ZN)B2Y
Fiber Optic Outdoor Buffered Fiber Cables (Maxi) A-DQ(ZN)2Y
A-DQ(ZN)B2Y
Fiber Optic Outdoor Buffered Fiber Stranded Cables
A-DQ(ZN)2Y
A-DQ(ZN)B2Y
A-DQ(ZN)B2Y
fiber combi MM+SM
A-DF(ZN)2Y
A-DF(ZN)B2Y
A-DF(ZN)2Y4Y
A-DF(ZN)2Y(SR)2Y
(acc. to ARCOR standard)
FIBER
OPTIC OUTDOOR LOOSE TUBE CABLES A-WF(ZN)2Y
/ A-WF(ZN)2Y4Y
FIBER
OPTIC OUTDOOR HYBRID CABLES (WITH VOLTAGE CONDUCTORS)
A-DSQ(ZN)B2Y
FIBER
OPTIC OUTDOOR HYBRID CABLES (WITH TELECOMMUNICATIONS
CONDUCTORS) A-DSF(L)(ZN)2Y
FIBER
OPTIC ADSS METAL-FREE AERIAL CABLES
FIBER
OPTIC MOBILE TRAILING CABLES: Mobile Cable
11Y
FIBER
OPTIC CABLES, FLEXIBLE A-V(ZN)11Y
Fiber Optic Cables for Industrial Applications
AT-VYY
INDUSTRY
HCS, I-V(ZN)Y11Y
INDUSTRY
HCS, AT-VQH(ZN)B2Y
INDUSTRY
HCS, A/I-DQ(ZN)BH
Plastic Fiber Cables POF/PE
POF/PA
is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.