Data & Computer Cable: RE-2Y(ST)Yv

Instrumentation Cable, Reinforced Outer Jacket

Sealcon, Inc, European & Domestic cable

RE-2Y(St)Yv Instrumentation cable, reinforced outer jacket, Sealcon,
Part-No. Description & No. Conductors x cross-sec. mm2, Color Outer
Diameter
mm
Copper Weight
kg/km
Weight
ca. kg/km
AWG
20099 RE-2Y(ST)Yv 1X2X0.5 black   8.2 15.0 74.0 20
20100 RE-2Y(ST)Yv 2X2X0.5 black

10.2

30.0 117.0 20
20101 RE-2Y(ST)Yv 4X2X0.5 black 11.5 50.0 140.0 20
20233 RE-2Y(ST)Yv 6X2X0.5 black 12.6 70.0 190.0 20
20102 RE-2Y(ST)Yv 8X2X0.5 black 13.8 90.0 215.0 20
20103 RE-2Y(ST)Yv 10X2X0.5 black 14.9 110.0 220.0 20
20104 RE-2Y(ST)Yv 12X2X0.5 black 15.7 130.0 280.0 20
20105 RE-2Y(ST)Yv 16X2X0.5 black 17.5 170.0 352.0 20
20106 RE-2Y(ST)Yv 20X2X0.5 black 18.8 210.0 385.0 20
20107 RE-2Y(ST)Yv 24X2X0.5 black 20.2 250.0 468.0 20
20108 RE-2Y(ST)Yv 36X2X0.5 black 24.1 370.0 656.0 20
20109 RE-2Y(ST)Yv 48X2X0.5 black 27.5 490.0 854.0 20
20149 RE-2Y(ST)Yv 1X2X0.75 black 7.9 20.0 74.0 18
20150 RE-2Y(ST)Yv 2X2X0.75 black 10.6 35.0 123.0 18
20151 RE-2Y(ST)Yv 4X2X0.75 black 11.8 65.0 164.0 18
20152 RE-2Y(ST)Yv 8X2X0.75 black 14.6 125.0 258.0 18
20153 RE-2Y(ST)Yv 10X2X0.75 black 16.1 154.0 305.0 18
20154 RE-2Y(ST)Yv 12X2X0.75 black 17.0 185.0 350.0 18
20155 RE-2Y(ST)Yv 16X2X0.75 black 19.0 245.0 445.0 18
20156 RE-2Y(ST)Yv 20X2X0.75 black 21.5 298.0 520.0 18
20157 RE-2Y(ST)Yv 24X2X0.75 black 23.2 365.0 620.0 18
20158 RE-2Y(ST)Yv 36X2X0.75 black 28.2 532.0 940.0 18
20159 RE-2Y(ST)Yv 48X2X0.75 black 32.0 708.0 1250.0 18
20125 RE-2Y(ST)Yv 1X2X1.3 black 9.4 31.0 102.0 -
20132 RE-2Y(ST)Yv 1X3X1.3 black 9.7 44.0 116.0 -
20126 RE-2Y(ST)Yv 2X2X1.3 black 11.7 62.0 161.0 -
20127 RE-2Y(ST)Yv 4X2X1.3 black 13.5 114.0 230.0 -
20234 RE-2Y(ST)Yv 6X2X1.3 black 16.0 168.0 310.0 -
20128 RE-2Y(ST)Yv 8X2X1.3 black 17.1 218.0 377.0 -
20129 RE-2Y(ST)Yv 12X2X1.3 black 19.3 322.0 515.0 -
20130 RE-2Y(ST)Yv 16X2X1.3 black 22.0 426.0 656.0 -
20131 RE-2Y(ST)Yv 24X2X1.3 black 26.5 684.0 952.0 -
20235 RE-2Y(ST)Yv 1X2X0.5 blue   8.2 15.0 74.0 20
20236 RE-2Y(ST)Yv 2X2X0.5 blue

10.2

30.0 117.0 20
20237 RE-2Y(ST)Yv 4X2X0.5 blue 11.5 50.0 140.0 20
20238 RE-2Y(ST)Yv 6X2X0.5 blue 12.6 70.0 190.0 20
20239 RE-2Y(ST)Yv 8X2X0.5 blue 13.8 90.0 215.0 20
20240 RE-2Y(ST)Yv 10X2X0.5 blue 14.9 110.0 220.0 20
20241 RE-2Y(ST)Yv 12X2X0.5 blue 15.7 130.0 280.0 20
20242 RE-2Y(ST)Yv 16X2X0.5 blue 17.5 170.0 352.0 20
20243 RE-2Y(ST)Yv 20X2X0.5 blue 18.8 210.0 385.0 20
20244 RE-2Y(ST)Yv 24X2X0.5 blue 20.2 250.0 468.0 20
20245 RE-2Y(ST)Yv 36X2X0.5 blue 24.1 370.0 656.0 20
20246 RE-2Y(ST)Yv 48X2X0.5 blue 27.5 490.0 854.0 20
20169 RE-2Y(ST)Yv 1X2X0.75 blue 7.9 20.0 74.0 18
20170 RE-2Y(ST)Yv 2X2X0.75 blue 10.6 35.0 123.0 18
20171 RE-2Y(ST)Yv 4X2X0.75 blue 11.8 65.0 164.0 18
20172 RE-2Y(ST)Yv 8X2X0.75 blue 14.6 125.0 258.0 18
20173 RE-2Y(ST)Yv 10X2X0.75 blue 16.1 154.0 305.0 18
20174 RE-2Y(ST)Yv 12X2X0.75 blue 17.0 185.0 350.0 18
20175 RE-2Y(ST)Yv 16X2X0.75 blue 19.0 245.0 445.0 18
20176 RE-2Y(ST)Yv 20X2X0.75 blue 21.5 298.0 520.0 18
20177 RE-2Y(ST)Yv 24X2X0.75 blue 23.2 365.0 620.0 18
20178 RE-2Y(ST)Yv 36X2X0.75 blue 28.2 532.0 940.0 18
20179 RE-2Y(ST)Yv 48X2X0.75 blue 32.0 708.0 1250.0 18
20247 RE-2Y(ST)Yv 1X2X1.3 blue 9.4 31.0 102.0 -
20255 RE-2Y(ST)Yv 1X3X1.3 blue 9.7 44.0 116.0 -
20248 RE-2Y(ST)Yv 2X2X1.3 blue 11.7 62.0 161.0 -
20249 RE-2Y(ST)Yv 4X2X1.3 blue 13.5 114.0 230.0 -
20250 RE-2Y(ST)Yv 6X2X1.3 blue 16.0 168.0 310.0 -
20251 RE-2Y(ST)Yv 8X2X1.3 blue 17.1 218.0 377.0 -
20252 RE-2Y(ST)Yv 12X2X1.3 blue 19.3 322.0 515.0 -
20253 RE-2Y(ST)Yv 16X2X1.3 blue 22.0 426.0 656.0 -
20254 RE-2Y(ST)Yv 24X2X1.3 blue 26.5 684.0 952.0 -
Technical Data
  • Special conductor insulation of PE
  • Conductor Resistance
    0.5 mm²: max. 39.2 Ohm/km
    0.75 mm²: max. 24.6 Ohm/km
    1.3 mm²: max. 14.2 Ohm/km
  • Temperature Range
    Flexing
    -5°C to +50°C (+23°F to +122°F)
    Fixed Installation
    -40°C to +70°C (-40°F to +158°F)
  • Operating Top Level Voltage
    max. 300 V (not for purposes of high current and power installation)
  • Test Voltage
    Conductor/conductor 2000 V
    Conductor/shield 1000 V
  • Insulation Resistance
    Min. 5 GOhm x km
  • Mutual Capacitance
    (Nominal value at 800 Hz)
    Conductor/conductor 0.5 mm²: 60 nF/km
    for 1 and 2 pairs: 75 nF/km
    Conductor/conductor 0.75 mm²: 65 nF/km
    for 1 and 2 pairs: 110 nF/km
    Conductor/conductor 1.3 mm²: 75 nF/km
    for 1 and 2 pairs: 100 nF/km
  • Inductance max. 0.75 mH/km
  • Cross-Talk Attenuation
    Min. 0.88 dB/km at 60 kHz
  • Minimum Bending Radius
    Approx. 7.5 x cable Ø
Approvals
RoHSCE pct
Cable Construction  
  • Bare copper stranded wires
    0.5 mm² (7x0.3 mm)
    0.75 mm² (7x0.37 mm)
    1.3 mm² (7x0.49 mm)
  • Conductor insulation of PE
  • Conductors colors with numbering
    pair:
    a-conductor black
    b-conductor white
    triple:
    a-conductor black
    b-conductor white
    c-conductor red
    with number print 1/1, 2/2, etc.
  • Conductors twisted to pairs with optimum pitch
  • Pairs stranded in layer + 1 communication conductor 0.5 mm², PE-insulated, orange (communication conductor for multi conductor version)
  • Conductor wrapping with foil
  • Electrostatic shield (ST) of plastics-coated metal foil and tinned drain-wire 0.5 mm² (7x0.3 mm)
  • PVC outer jacket, reinforced
  • Color: Black (RAL 9005) or Blue (RAL 5015)
  • With blue outer jacket for hazardous areas to hazard type -i- for intrinsically safe installation according to DIN EN 60079-14 and IEC 60079-14 section 12.2.2 (VDE 0165 part 1)
  • Wall-thickness to DIN VDE 0816, part 1, table 7, col. 1
Application  
Instrumentation cables are used in data processing and process control.
Instrumentation cables are suitable for fixed installations in damp locations, in open spaces and for underground laying.
CE Approval = The product is conformed with the EC Low-Voltage Directive 73/23/EEC and 93/68/EEC.
Properties  
  • Self-extinguishing and flame retardant according to VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B)
  • The electrostatic shield protects the shielded pairs against outer electrostatic interference fields
  • Low level of line attenuations and low mutual capacitances enable long transmission distances and fast pulse acceleration
  • The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers
Note  
  • AWG sizes are approximate equivalent values. The actual cross-section is in mm².
  • Copper weight including communication conductor and drain-wire
Cable Accessories  
  • Coming Soon!
Cable Technical Data Construction and ApplicationProperties and Note Accessories
quote
Items For Quote

   
quote
box
Sealcon is the Exclusive Importer of HUMMEL products. We offer over 6,000 different Types and Sizes of RoHS Compliant Liquid Tight Strain Relief Fittings, Cord Grips, Cable Glands, Circular Connectors, Conduit System, Industrial Enclosures and Other Related Cable Management Products which are rated the best in the industry.
7374 S. Eagle Street
Centennial, CO 80112-4221 USA
Toll Free: 800-456-9012 / 303-699-1135 FAX: 303-680-5344
Valid XHTML 1.0 Transitional
To Top of Page Top of Page

Copyright © Sealcon All Rights Reserved
|Domestic & International Cables|Enclosures |Liquid Tight Strain Relief Fittings & Accessories|
|Circular Connectors|Conduit System|Pneumatics|Cable Index|Enclosure Index|Search|
|Media|Site Map|Company Overview|Contact|Privacy Policy|Copyright Notice|