Control Cable: JZ-600-Y-CY UL/CSA

Flexible, Number Coded, 0.6/1kV, Copper-Shielded, EMI Preferred Type

JZ-600-Y-CY_UL_CSA

https://www.hitechcontrols.com/cables/control_cable/pvc_shielded/jz-600_y_cy_ul_csa.html

Application:

Wiring cable for measuring and controlling purposes in tool machinery, conveyor belts and production lines, for plant installations, air conditioning and in steel production plants and rolling mills. Suitable for installation for flexible use for medium mechanical stresses with free movement without tensile stress or forced movements in dry, moist and wet rooms as well as outside (fixed installation). Is not suitable to be used as direct burial or as underwater cable. Interference-free transmission of signals and pulses is assured by the high degree of shielding.
EMI = Electromagnetic Interference
To optimize the EMI features we recommend a large round contact of the copper braiding on both ends.

Properties

  • Extensively oil resistant
  • For chemical resistance, see table Technical Information
  • Resistant to ultra violet rays (building with black jacket)
  • PVC self-extinguishing and flame retardant according to DIN VDE 0482-332-1-2, DIN EN 60332-1-2 / IEC 60332-1 (equivalent DIN VDE 0472 part 804 test method B) VW1, FT1
  • The materials used in manufacture are cadmium-free, contain no silicone and are free from substances harmful to the wetting properties of lacquers

Cable Construction

  • Bare copper, fine wire conductors according to DIN VDE 0295 cl. 5, BS 6360 cl. 5 and IEC 60228 cl. 5
  • Special PVC conductor insulation TI2, to DIN VDE 0281 part 1, class 43 UL Std. 1581
  • Black conductors with sequential numbering imprinted in white, according to DIN VDE 0293
  • Green-yellow earth conductor in the outer layer (3 conductors and above)
  • Conductors stranded in layers with optimal lay-length
  • PVC-insulated inner jacket TM2, to DIN VDE 0281 part 1, class 43 UL-Std. 1581
  • Braided shielding of tinned copper wires, coverage approx. 85%
  • Special PVC outer jacket TM2, to DIN VDE 0281 part 1 class 43 UL Std. 1581
  • Color: Black (RAL 9005) or Gray (RAL 7001)

Technical Data

  • Special PVC control cables
  • Adapted to DIN VDE 0276 part 627, DIN VDE 0281 part 13, with insulation thickness for 1 kV type and UL Std. 758 Style 21179
  • Temperature Range: Flexing -5°C to +80°C (+23°F to +176°F), Fixed Installation -40°C to +90°C (-40°F to +194°F)
  • Nominal voltage U 1000 V
  • Test voltage 4000 V
  • Breakdown voltage min. 8000 V
  • Insulation Resistance Min. 20 MOhm x km
  • Power Rating According to DIN VDE 0298
  • Minimum Bending Radius Flexing 10x cable Ø, Fixed Installation 5x cable Ø
  • Radiation Resistance Up to 80×106 cJ/kg (up to 80 Mrad)
  • Coupling Resistance Max. 250 Ohm/km